Dryer ducts- The “Forgotten About” Fire Hazard

Written by:  Jim Allhiser  President/Inspector


The consumer product safety commission estimated that in 1998 clothes dryers were associated with 15,600 fires, which resulted in 20 deaths and 370 injuries!
A vast majority of these fires could have been prevented with a little home owner style maintenance.
The duct work that exhausts all of that warm dryer air is usually the culprit, and as far as routine home owner maintenance, is usually completely forgotten about.
Ideally these ducts should be hard and completely smooth.  This minimizes the slow down of the hot air that will cause lint to build up.   This means that the flexible corrugated metal ducts that all do-it-youselfers love are terrible.  Everyone of those little ridges in the duct pipe create turbulence that slows down the flow of air.

Fire hazard or Dryer duct? Both.

Even with hard ducting the joints are a critical point of contention.  With forced air furnaces, the joints between one hard duct to another, are usually secured with sheet metal screws.  If this technique is put into practice with dryer ducts all of those sharp little screws that are in the flow of air act as lint catchers.
The moral of this story is:  If you have not cleaned your dryer and ducting recently it is time to do so.  If you have an issue with the duct and need to install a new duct, it is usually best to hire a professional to install a HARD DUCT with proper seams that are TAPED and not screwed together.
My job as a home inspector requires me to crawl and poke around other people’s homes every day and this is one of the most neglected fire hazard that I see.
Jim Allhiser
President/Inspector
All content is Copy written and is the property of Perfection Inspection Inc. Any usage that is not expressly permitted by Perfection Inspection Inc. is  infringement and is punishable by law.
Bookmark and Share

That’s what that thingy is for??

The most important part of a good home inspection is the education about the home.  Above and beyond the defects that good home inspectors will find, helping the new home owners understand the weird knobs and switches that are in a typical home is really where good inspectors earn their wage.
One type of knob in particular that I see often in more recently built homes is the “hose bib winterization valve.”
It seems simple enough however they usually are not anywhere near the hose bib (outside water faucet)!
In a two-story home, these valves are usually stuffed under an upstairs bathroom sink.  The placement is good because if you shut the water off and open the bleed valve the water will readily drain out the outside water faucet.
If you have a recently built home and see one of these under the sink:
you now know what that weird thingy is for.


Jim Allhiser

President/Inspector
http://SalemOregonHomeInspections.com
503.508.4321         jallhiser@perfectioninspectioninc.com

“Always on the cutting edge”