Grounded outlets, GFCI’s, seatbelts and airbags

It is very common for me to inspect homes that are older than the 1960s that have three-prong outlets that are not grounded.

Originally these outlets would have been two-prong, with one side acting as the “hot” and the other side acting as the “neutral.”  The hot is, for the purposes of my discussion, the supply of power and the neutral is the return.  When well-meaning homeowners try to “improve” their original two-prong outlets with three-prong outlets they very rarely think about the third prong and what its purpose might be and the fact that there is no wire for the third hole in the outlet.

When I often describe what is going on, my client’s thoughts jump to their electrical devices not functioning properly.  The proper function of electrical devices is not really what we are dealing with when a ground wire is missing.  The ground wire is merely a backup for the neutral/return, and its purpose is to protect the occupant (you) from shock/electrocution and has very little to do with proper function.  

There is a slight caveat when referring to grounds, computers and some newer televisions.  Surge protectors take excess electricity and dump it into the ground leg.  If no ground is present the surge protector will not function.  I have also heard that some newer televisions will not function at all without a ground.  This is a liability protection for the TV manufacturer that is built into some newer TVs.car

To put this in a more understandable analogy I compare this situation to a car.   Ground wires are kind of like seat belts.  They protect the person from injury and older homes (just like vehicles and seat belts) didn’t have them.  Grounds/seatbelts really don’t affect the way the car drives/electrical device operates.  They are merely safety devices that will protect you from injury.  Grounds are not required in the 1950s or older homes, just like seat belts aren’t required in that age car.  Vintage two-prong plugs are relatively safe because it is obvious that there is not a ground, and you cannot plug in a device that wants the ground prong.

The three prong adapter is screwed into a box that is not grounded.  This is not a safe ground

Three-prong adaptors are devices that allow you to plug a three-prong plug into a two-prong outlet. When three-prong adaptors are used it is VERY important that the electrical box is grounded.  You might be wondering what in the world is a grounded box?   In the early to mid 60’s the nonmetallic wiring changed from a strictly two-wire (one hot, one neutral) to a three-wire (one hot, one neutral, and a newly added ground).  The wiring changed but many of the plugs (two prong) did not change.  The only way to verify if the box is grounded is with a tester.  Plug one side into the hot and touch the other to the screw in the center of the outlet.  If the outlet is grounded there will be a completed circuit and the light will glow.  This type of grounded box is the ONLY time that the three-prong adaptors should be used on a two-prong plug! 

 

 Now let’s say the home we have an interest in was pre 60’s and none of the outlets are grounded, what do you do now?   Always, always, always talk to a licensed professional electrician.  The conditions I describe are totally generalities and your specific situation may have special circumstances that make these general recommendations less than ideal or even DANGEROUS!  Now with that disclaimer out of the way……..        

Grounds are especially important around water sources.   Kitchens, bathrooms, garages, and exterior plugs should all be grounded at the very least.  These areas are the places where you are most likely to become a great source for electricity to try to jump to ground through you.

  • The ideal way to ensure these shock/electrocution-prone areas are protected is by running a new, properly wired circuit from the panel to the plug.
  • Boot-legging a ground may be an option but TALK TO YOUR ELECTRICIAN FIRST!!  Boot-legging a ground is where you run a single conductor (wire) from the outlet to a bond (clamp) on a cold-water pipe.  Bootlegging is not ideal, and you may be unable to find a licensed professional electrician to help you with this (that should tell you something!)
  • The installation of GFCIs on the ungrounded circuits.  This is kind of like installing an airbag in a car with no seat belt.  It is safer than no seat belt, and no airbag but it is not as safe as a properly installed seat belt and airbag.  The installation of GFCIs on ungrounded circuits will not provide an equipment ground and should be labeled as such.  This means that surge protectors will not protect equipment from surges and your surge protectors are useful only as paperweights.

I have used this analogy for a few years, and it seems to hold up pretty well when describing this electrical theory.  If you have any questions on how the electricity works in your home, please contact your local electrician or of course your favorite home inspector!

 

4 comments

  1. So what if someone tied the ground to the nuetral white wire at the plug? The tester would probably say everything is fine since they are connected at the breaker panel. I could never understand the theory of that.

    1. I don’t exactly understand it either Todd. The National Electrical Code calls the neutral the “grounding conductor” and the ground the “grounded conductor.” Pretty confusing if you ask me.
      The neutral is a designed to be a voltage carrying leg of the circuit. The ground is strictly a back up. I am curious about your question and what the tester would read. Let me get back to you after some testing.